Technical Data
Datasheet of Inverter (SMILE-G3 Three Phase Inverter)
|
|
|
| |
| ||||
Recommended Max. PV Power |
|
|
| |
Max. PV Input Voltage |
| |||
Rated Voltage |
| |||
Start-up Voltage |
| |||
MPPT Voltage Range |
| |||
Max. Input Current per MPPT |
| |||
Max. Short Circuit Current per MPPT |
| |||
MPPT Number |
| |||
Back feed current |
| |||
Max. Input Strings Number per MPPT |
| |||
Surge Category in Accordance with IEC 62109-1 |
| |||
| ||||
Battery Type |
| |||
Battery Voltage Range |
| |||
Nominal Battery voltage |
| |||
Max. Charge Power |
|
|
| |
Max. Discharge Power |
|
|
| |
Max. Charge/ Discharge Current |
| |||
Communication |
| |||
Back feed current |
| |||
| ||||
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
Max. Continuous Output Apparent Power |
|
|
| |
Max. Output Current |
|
|
| |
MAX.Fault Current |
| |||
|
| |||
|
| |||
|
| |||
|
| |||
|
| |||
| ||||
|
|
|
| |
Rated Apparent Output Power |
|
|
| |
|
|
|
| |
Max. Continuous Output Power |
|
|
| |
Max. Continuous Output Apparent Power |
|
|
| |
Max. Output Power ≤ 30s |
|
|
| |
Max. Output Apparent Power ≤ 30s |
|
|
| |
Max. Output Power ≤ 1s |
|
|
| |
Max. Output Apparent Power ≤ 1s |
|
|
| |
|
| |||
Rated Output Voltage |
| |||
|
| |||
| ||||
|
| |||
|
| |||
|
|
|
| |
|
|
|
| |
|
|
|
| |
| ||||
Rated Output Power |
|
|
| |
MAX. Apparent Output Power |
|
|
| |
Rating Grid Output Current |
|
|
| |
|
| |||
|
| |||
|
| |||
|
| |||
Power Factor | >0.99 (0.8 leading to 0.8 lagging) | |||
Protection Class | l | |||
Pollution Degree | ll | |||
Overvoltage Category | lll | |||
Surge Category in Accordance with IEC 60664-1 | II | |||
DVC | DVC-C | |||
Anti-islanding protection Method | Frequency shift | |||
| ||||
Max. Efficiency, ηmax | 97.8% | 97.8% | 97.8% | |
European Weighted Efficiency, ηEU | 97.0% | 97.0% | 97.0% | |
| ||||
Anti-Islanding Protection | Integrated | |||
Insulation Resistor Detection | Integrated | |||
Residual Current Monitoring Unit | Integrated | |||
Output over Current Protection | Integrated | |||
Output Short Protection | Integrated | |||
Output Overvoltage Protection | Integrated | |||
PV Reverse Polarity Protection | Integrated | |||
PV Overvoltage Protection | Integrated | |||
PV Switch | Integrated | |||
Battery Breaker | Integrated | |||
| ||||
Dimensions (W*D*H) | 590*205*416 mm | |||
Weight | 27.5 kg | |||
Topology | Transformerless | |||
Operation Temperature Range | -25 to +60 °C | |||
Max. Permissible Value for Relative Humidity (Condensing) | 100% | |||
Ingress Protection | IP65 | |||
Display | LED | |||
Noise Emission | <35 dB(A) @1m | |||
Cooling Concept | Natural convection | |||
Max. Operating Altitude above MSL | 3000 m | |||
| ||||
PV Connection | Vaconn D4 connectors | |||
Grid Connection | Plug-in connector | |||
Backup Connection | Plug-in connector | |||
BAT Connection | Amphenol H4 connectors | |||
Communication | LAN, Wi-Fi | |||
Grid Connection Standard | G98, VDE-AR-N 4105, EN 50549-10, VDE 0126, CEI 0-21, C10/11, TOR Erzeuger, MEA, PEA, AS/NZS 4777.2 | |||
Safety/ EMC Standard | IEC62109-1/-2 IEC/EN61000-6-1/2/3/4 | |||
Warranty | 10 Years Product Warranty | |||
|
|
| ||
| ||||
Recommended Max. PV Power |
|
| ||
Max. PV Input Voltage |
| |||
Rated Voltage |
| |||
Start-up Voltage |
| |||
MPPT Voltage Range |
| |||
Max. Input Current per MPPT |
| |||
Max. Short Circuit Current per MPPT |
| |||
MPPT Number |
| |||
Back feed current |
| |||
Max. Input Strings Number per MPPT |
| |||
Surge Category in Accordance with IEC 62109-1 |
| |||
| ||||
Battery Type |
| |||
Battery Voltage Range |
| |||
Nominal Battery voltage |
| |||
Max. Charge Power |
|
| ||
Max. Discharge Power |
|
| ||
Max. Charge/ Discharge Current |
| |||
Communication |
| |||
Back feed current |
| |||
| ||||
|
|
| ||
|
|
| ||
|
|
| ||
|
|
| ||
Max. Continuous Output Apparent Power |
|
| ||
Max. Output Current |
|
| ||
MAX.Fault Current |
| |||
|
| |||
|
| |||
|
| |||
|
| |||
|
| |||
| ||||
|
|
| ||
Rated Apparent Output Power |
|
| ||
|
|
| ||
Max. Continuous Output Power |
|
| ||
Max. Continuous Output Apparent Power |
|
| ||
Max. Output Power ≤ 30s |
|
| ||
Max. Output Apparent Power ≤ 30s |
|
| ||
Max. Output Power ≤ 1s |
|
| ||
Max. Output Apparent Power ≤ 1s |
|
| ||
|
| |||
Rated Output Voltage |
| |||
|
| |||
| ||||
|
| |||
|
| |||
|
|
| ||
|
|
| ||
|
|
| ||
| ||||
|
|
| ||
Rated Apparent Output Power |
|
| ||
Rating Grid Output Current |
|
| ||
|
| |||
|
| |||
|
| |||
|
| |||
Power Factor | >0.99 (0.8 leading to 0.8 lagging) | |||
Protection Class | l | |||
Pollution Degree | ll | |||
Overvoltage Category | lll | |||
Surge Category in Accordance with IEC 60664-1 | II | |||
DVC | DVC-C | |||
Anti-islanding protection Method | Frequency shift | |||
| ||||
Max. Efficiency, ηmax | 97.8% | 97.8% | ||
European Weighted Efficiency, ηEU | 97.0% | 97.0% | ||
| ||||
Anti-Islanding Protection | Integrated | |||
Insulation Resistor Detection | Integrated | |||
Residual Current Monitoring Unit | Integrated | |||
Output over Current Protection | Integrated | |||
Output Short Protection | Integrated | |||
Output Overvoltage Protection | Integrated | |||
PV Reverse Polarity Protection | Integrated | |||
PV Overvoltage Protection | Integrated | |||
PV Switch | Integrated | |||
Battery Breaker | Integrated | |||
| ||||
Dimensions (W*D*H) | 590*205*416 mm | |||
Weight | 27.5 kg | |||
Topology | Transformerless | |||
Operation Temperature Range | -25 to +60 °C | |||
Max. Permissible Value for Relative Humidity (Condensing) | 100% | |||
Ingress Protection | IP65 | |||
Display | LED | |||
Noise Emission | <35 dB(A) @1m | |||
Cooling Concept | Natural convection | |||
Max. Operating Altitude above MSL | 3000 m | |||
| ||||
PV Connection | Vaconn D4 connectors | |||
Grid Connection | Plug-in connector | |||
Backup Connection | Plug-in connector | |||
BAT Connection | Amphenol H4 connectors | |||
Communication | LAN, Wi-Fi | |||
Grid Connection Standard | G98, VDE-AR-N 4105, EN 50549-10, VDE 0126, CEI 0-21, C10/11, TOR Erzeuger, MEA, PEA, AS/NZS 4777.2 | |||
Safety/ EMC Standard | IEC62109-1/-2 IEC/EN61000-6-1/2/3/4 | |||
Warranty | 10 Years Product Warranty | |||
|
|
| |
| |||
Recommended Max. PV Power |
|
| |
Max. PV Input Voltage |
| ||
Rated Voltage |
| ||
Start-up Voltage |
| ||
MPPT Voltage Range |
| ||
Max. Input Current per MPPT |
| ||
Max. Short Circuit Current per MPPT |
| ||
MPPT Number |
| ||
Max. Input Strings Number per MPPT |
| ||
Surge Category in Accordance with IEC 62109-1 |
| ||
Back feed current |
| ||
| |||
Battery Type |
| ||
Battery Voltage Range |
| ||
Nominal Battery voltage |
| ||
DVC |
| ||
Max. Charge Power |
|
| |
Max. Discharge Power |
|
| |
Max. Charge/ Discharge Current |
| ||
Communication |
| ||
| |||
|
|
| |
|
|
| |
|
|
| |
|
|
| |
Max. Continuous Output Apparent Power |
|
| |
Max. Output Current |
|
| |
Max fault current |
| ||
THDV(@linear load) |
| ||
DVC |
| ||
Back feed current |
| ||
|
| ||
|
| ||
| |||
|
|
| |
Rated Apparent Output Power |
|
| |
|
|
| |
Max. Continuous Output Power |
|
| |
Max. Continuous Output Apparent Power |
|
| |
Max. Output Power ≤ 30s |
|
| |
Max. Output Apparent Power ≤ 30s |
|
| |
Max. Output Power ≤ 1s |
|
| |
Max. Output Apparent Power ≤ 1s |
|
| |
|
| ||
Rated Output Voltage |
| ||
|
| ||
| |||
|
| ||
|
| ||
|
|
| |
|
|
| |
|
|
| |
| |||
|
|
| |
Rated Apparent Output Power |
|
| |
Rating Grid Output Current |
|
| |
|
| ||
|
| ||
|
| ||
|
| ||
Power Factor | >0.99 (0.8 leading to 0.8 lagging) | ||
Protection Class | l | ||
Overvoltage Category | lll | ||
Pollution Degree | ll | ||
DVC | DVC-C | ||
Anti-islanding protection Method | Frequency shift | ||
Surge Category in Accordance with IEC 60664-1 | II | ||
| |||
Max. Efficiency, ηmax | 97.8% | 97.8% | |
European Weighted Efficiency, ηEU | 97.0% | 97.0% | |
| |||
Anti-Islanding Protection | Integrated | ||
Insulation Resistor Detection | Integrated | ||
Residual Current Monitoring Unit | Integrated | ||
Output over Current Protection | Integrated | ||
Output Short Protection | Integrated | ||
Output Overvoltage Protection | Integrated | ||
PV Reverse Polarity Protection | Integrated | ||
PV Overvoltage Protection | Integrated | ||
PV Switch | Integrated | ||
Battery Breaker | Integrated | ||
| |||
Dimensions (W*D*H) | 590*205*416 mm | ||
Weight | 27.5 kg | 28 kg | |
Topology | Transformerless | ||
Operation Temperature Range | -25 to +60 °C | ||
Max. Permissible Value for Relative Humidity (Condensing) | 100% | ||
Ingress Protection | IP65 | ||
Display | LED | ||
Noise Emission | <45 dB(A) @1m | ||
Cooling Concept | Natural convection | Smart Fan cooling | |
Max. Operating Altitude above MSL | 3000 m | ||
| |||
PV Connection | Vaconn D4 connectors | ||
Grid Connection | Plug-in connector | ||
Backup Connection | Plug-in connector | ||
BAT Connection | Amphenol H4 connectors | ||
Communication | LAN, Wi-Fi | ||
Grid Connection Standard | G98, VDE-AR-N 4105, EN 50549-10, VDE 0126, CEI 0-21, C10/11, TOR Erzeuger, MEA, PEA, AS/NZS 4777.2 | ||
Safety/ EMC Standard | IEC62109-1/-2 IEC/EN61000-6-1/2/3/4 | ||
Warranty | 10 Years Product Warranty | ||
Datasheet of Battery
Datasheet of Battery SMILE-G3-BAT-3.8S
Model | SMILE-G3-BAT-3.8S |
Battery type | LFP (LiFePO4) |
Rated capacity | 38 Ah |
Weight | 38.5 kg |
Dimension (W*D*H) | 610*212*435 mm |
Ingress protection | IP21 |
Installed energy | 3.84 kWh |
Usable energy | 3.65 kWh |
DoD | 95% |
Nominal voltage | 96 V |
Operating voltage range | 90 to 105.6 V |
Max. continuous charge current* | 40 A |
Max. continuous discharge current* | 40 A |
Operating temperature range | Charge:0<T≤50 ℃ Discharge:-10<T≤50 ℃ |
Monitoring parameters | System voltage, current, cell voltage, cell temperature, PCBA temperature |
BMS communication | CAN |
System | |
Safety | IEC62619 / IEC63056 / IEC62040 |
Transportation | UN38.3 |
* Max. charge/discharge current derating may occur with changes in temperature and SOC
Datasheet of Battery SMILE-G3-BAT-4.5S
Model | SMILE-G3-BAT-4.5S |
Battery type | LFP (LiFePO4) |
Rated capacity | 47.5 Ah |
Weight | 53 kg |
Dimensions (W*D*H) | 610*212*435 mm |
Ingress protection | IP65 |
Installed energy | 4.8 kWh |
Usable energy | 4.56 kWh |
DoD | 95% |
Nominal voltage | 96 V |
Operating voltage range | 90 ~ 105.6 V |
Max. charge current* | 50 A |
Max. discharge current* | 50 A |
Operating temperature range | Charge: -20 ≤ T ≤ 50 °C Discharge: -20 ≤ T ≤ 50 °C |
Monitoring parameters | System voltage, current, cell voltage, cell temperature, PCBA temperature |
BMS communication | CAN |
System | |
Safety | IEC62619 / IEC63056 / IEC62040 |
Transportation | UN38.3 |
* Max. charge/discharge current derating may occur with changes in temperature and SOC.
Datasheet of Battery SMILE-G3-BAT-9.3S
Model | SMILE-G3-BAT-9.3S |
Battery type | LFP (LiFePO4) |
Rated capacity | 95 Ah |
Weight | 81 kg |
Dimensions (W*D*H) | 610*212*634 mm |
Ingress protection | IP65 |
Installed energy | 9.6 kWh |
Usable energy | 9.3 kWh |
DoD | 95% |
Nominal voltage | 96 V |
Operating voltage range | 90 ~ 105.6 V |
Max. charge current* | 52.5 A |
Max. discharge current* | 52.5 A |
Operating temperature range | Charge: -20 ≤ T ≤ 50 °C Discharge: -20 ≤ T ≤ 50 °C |
Monitoring parameters | System voltage, current, cell voltage, cell temperature, PCBA temperature |
BMS communication | CAN |
System | |
Safety | IEC62619 / IEC63056 / IEC62040 |
Transportation | UN38.3 |
* Max. charge/discharge current derating may occur with changes in temperature and SOC.