Add VitaMate batteries
Match the charge levels before disconnecting and installing.
Prepare and match the charge levels
Before connecting a new battery, its state of charge should be close to that of the batteries already in the system.
- Existing battery: 60%
- New battery: 63%
- Difference ≤5 percentage points
Example: 60% and 63% differ by 3 percentage points, meeting the manual’s requirement.
DANGER
Do not connect if the difference exceeds 5 percentage points
A large difference may prevent correct calibration and full use of the total capacity. If you cannot confirm the new battery’s state of charge, contact your supplier or installer. Never try connecting it while the system is powered.
Install the new battery
Check the charge levels and shut down the existing system
Disconnect the AC power supply and follow the shutdown sequence.
Check the lowest connector position again
After expansion, the Bottom Connector must still be underneath the lowest VitaMate in the complete system.
Stack and secure as shown in the quick guide
Use no more than 3 VitaMate modules. The main unit must always be at the top. Secure the bracket and the screws on both sides.

Checks after expansion
- Every module is securely connected and fixed, with the connector fitted underneath the lowest battery.
- No fault indicator is lit after start-up.
- Check in the app that the detected battery modules and capacity match the installed configuration.
- 1 VitaMate: Total installed energy: 8 kWh.
- 2 VitaMate modules: Total installed energy: 12 kWh.
- 3 VitaMate modules: Total installed energy: 16 kWh.